Product Introduction

 

 

MTP/MPO cable assemblies provide multi-fiber connectivity inside high-density data center architectures. A single MTP/MPO interface houses 8, 12, 16, 24, or 32 fibers within a footprint comparable to a standard SC duplex connector, reducing rack space and cable management complexity. Assemblies utilize precision molded MT ferrules, guide pins, and ruggedized jacket structures to maintain optical alignment across 40G, 100G, 200G, 400G, and 800G Ethernet links.

 

 
  • Mpo To Lc Breakout Cables

    MPO to LC breakout cables are generally composed of four components: the main cable, sub-cables, splitters, and connectors. The main cable adopts multi-core optical fiber cable, which facilitates

  • Mtp Mpo Fiber Breakout Cable

    MPO MTP breakout patch cords are generally composed of four components: the main cable, sub-cables, splitters, and connectors. The main cable adopts multi-core optical fiber cable, which facilitates

  • MPO MTP Harnesses Cable

    MPO MTP Harnesses Cable Patchcord OM4 offers a flexible and cost-effective solution. By weaving together 8F/12F MOP MTP Trunk Fiber Patchcords, this innovative product can realize a wide range of

  • MPO MTP Trunk Cable

    MPO MTP trunk cables connect MTP MPO modules together as a permanent link. They facilitate rapid deployment of high-density backbone cabling in data centers and other high density fiber

  • Mtp To Lc Cassette

    MPO to LC Cassette capable of accepting 6-24 fibers. These cassettes are suitable for use with Singlemode, Multimode 62.5 and 50um, as well as Laser Optimized, OM3 applications and are available

  • Mpo To Lc Cassette

    MTP to LC cassette is mainly used for data center with the security Transactions between MPO pre-terminated trunk cable and LC or SC connectors. They are installed in the 19 1U-3U fiber patch panels.

  • Mpo Breakout Cassette

    The MTP MPO trunk micro cable assembly facilitates rapid deployment of high density backbone cabling, in data centres and other high-fibre environments,reducing network installation or

  • Mpo Loopback Cable

    MPO and MTP are the MT series. Small size, Multi-channel is the most prominent feature, which greatly facilitates the high-density wiring. The MT series connectors have been widely applied to the

  • MTP MOP Single Mode Loopback

    The MPO Single Mode Loopback is a specialized passive optical component engineered for testing, troubleshooting, and validating single-mode fiber optic networks, especially high-density systems in

  • MTP MOP Multimode Loopback

    MTP MPO Multimode Loopback is used to test network system in the signal comes back, through the echo signal, can detect the network link in the various potential abnormalities, the test is widely

  • Mpo Mtp Loopback

    MPO MTP Loopback is a type of duplex or multi-fiber connector in which both ends of fibers are in the same connectorSignals input into a loopback have no change and get back to the loopback directly.

  • MPO 12C Patch Panel

    MTP MPO 12C patch panel Cassettes fitted with 12 Fibers and have LC/SC/FC adapters on the front side and MTP/MPO at the rear. MPO/ MTP Cassettes are tailor-made for 10G/40G/100G migration Ethernet

First 12 Last
 
 
Product Types / Configurations
 
01/

Trunk Cables: Backbone cabling linking switches, patch panels, and MDA zones. Configured with pinned-to-unpinned MTP/MPO connectors.

02/

Harness / Breakout Cables: Transition assemblies converting a multi-fiber MTP/MPO connector into discrete LC, SC, or FC connectors (e.g., 1x MTP-12 to 6x LC duplex).

03/

Conversion Cables: Direct linking solutions matching differing fiber counts without active transceivers, such as 2x MTP-12 to 3x MTP-8 modules for 40G-to-100G migration.

04/

Low-Loss Elite Assemblies: Premium configurations built using low-loss US Conec MTP connectors and precision-sorted fiber to support tight channel loss budgets in multi-link hyperscale topologies.

 

 

Key Specifications

 

 

Parameter

Standard Grade

Low-Loss (Elite) Grade

Connector Type

Standard MPO / US Conec MTP

US Conec MTP Elite

Insertion Loss (IL)

<= 0.70 dB (Multi-mode), <= 0.75 dB (Single-mode)

<= 0.35 dB (Multi-mode), <= 0.35 dB (Single-mode)

Return Loss (RL)

>= 20 dB (PC), >= 50 dB (APC)

>= 30 dB (PC), >= 60 dB (APC)

Fiber Count Options

8, 12, 16, 24, 32 Fibers

8, 12, 16, 24, 32 Fibers

Fiber Types

OS2 (9/125 um), OM3/OM4/OM5 (50/125 um)

OS2, OM3, OM4, OM5

Operating Temperature

-20 deg.C to +70 deg.C

-20 deg.C to +70 deg.C

Jacket Material

LSZH, OFNP, PVC, Armored

LSZH, OFNP, PVC, Armored

Durability

<= 0.2 dB change after 500 matings

<= 0.2 dB change after 500 matings

 

How to Select

Determine Fiber Count and Speed:

Match the transceiver lane configuration. For example, 40G QSFP+ uses 12-fiber MPO (8 active fibers), while 400G SR8 requires 16-fiber MTP interfaces.


Verify Polarity Method:

Select Method A, Method B, or Method C based on your switch-to-switch or patch panel architecture to maintain proper transmit-to-receive (Tx-Rx) alignment.

Calculate Channel Loss Budget:

Choose Standard Grade for short rack runs or Low-Loss Elite Grade when links pass through multiple cassette modules or patch panels.

Select Pin Configuration:

Ensure correct mating compatibility. Trunk cables require one end pinned (male) and the opposite end unpinned (female). Harness cables are typically unpinned at the MTP end to interface with active switch ports.

Jacket and Compliance Rating:

Specify LSZH for confined indoor routing, OFNP (Plenum) for raised flooring and air-handling spaces, or corrugated steel armored jackets for harsh pathways.

 

Applications

 

Hyperscale & Enterprise Data Centers:

High-density switch-to-switch backbone routing inside MDA, HDA, and EDA zones.

Storage Area Networks (SAN):

High-speed fibre channel infrastructure linking core storage arrays with directors.

MPO MTP Harnesses Cable

Telecommunications Central Offices:

High-density optical distribution frames (ODF) managing dense optical line terminal (OLT) connections.

High-Performance Computing (HPC):

Low-latency cluster interconnects requiring strict multi-fiber insertion loss tolerances.

 

 
 
Customization Options
01.

Breakout Lengths:

Tailored fan-out leg lengths (e.g., 0.5m, 1m) and staggering configurations to fit specific patch panel entry trays.

02.

Pulling Eye Kits:

Factory-installed pulling eyes on trunk cables to protect connectors during harsh underground conduit or cable tray pulls.

03.

Jacket Colors:

Specific outer sheath coloring aligned with TIA-598 standards or proprietary facility color-coding (Aqua for OM3, Erika Violet for OM4, Lime Green for OM5, Yellow for OS2).

04.

Labeling:

Custom barcode labeling, serialization, and length indicators printed on heat-shrink tubing at both cable ends.

 

Manufacturing & Quality Control
 

End-Face Geometry Interferometer Inspection:

Every ferrule is scanned using 3D interferometers to measure apex offset, fiber height, and radius of curvature, verifying compliance with IEC 61755-3 standards.

Microscopic End-Face Inspection:

400x magnification checks for surface scratches, pits, and residue on the cladding and core zones. Test reports ship inside every individual package.

100% Optical Testing:

Insertion loss and return loss tested individually on every channel prior to packaging using calibrated Encircled Flux (EF) compliant light sources.

Automated Polishing Equipment:

Multi-axis polishing machines eliminate fiber undercut and protrusion defects on MT ferrules.

 

Packaging & Delivery

 
 
01
 

Packaging Structure:

Individual antistatic blister packs or sealed zip bags containing individual test data sheets. Bulk master cartons reinforced with corner protectors.

 
02
 

Traceability:

Barcode labels on every spool and package showing batch number, length, IL/RL test results, and operator ID.

 
03
 

Lead Time:

Standard configurations ship within 5 to 7 business days; custom high-volume trunk orders ship within 10 to 14 business days.

Mtp Mpo Fiber Breakout Cable

 

Mpo To Lc Breakout Cables

 

Why This Product for Your Project

Elimination of Insertion Loss Bottlenecks: Low-loss US Conec MTP connectors ensure compliance with strict multi-vendor IEEE link loss budgets.
Direct Factory Verification: Complete elimination of blind batch sampling; every single multi-fiber assembly includes its specific interferometric and optical test report.
Mechanical Reliability: Precision guide-pin tolerances and ruggedized strain relief boot designs withstand repeated high-density port insertions without mechanical degradation.

 

 

fAQ

 

 

Q: How do I determine whether to use Method A, B, or C polarity for my structured cabling?

A: Method A uses straight-through fiber positioning with key-up to key-down adapters, maintaining fiber position 1 to 1 across the link. Method B uses key-up to key-up adapters, reversing fiber positions (1 to 12) to match parallel optics transceiver requirements where Tx maps directly to Rx. Method C pairs adjacent fibers (1-to-2, 3-to-4) in a reversed pair configuration, typically used for duplex application migration. Verify your switch transceiver datasheet before specifying.

Q: What is the difference between standard MPO and US Conec MTP connectors?

A: The MTP connector is a high-performance MPO variant engineered with tighter mechanical tolerances. It features a floating ferrule to improve mechanical mating performance under load, removable housing for gender conversion, and elliptical guide pins made of stainless steel to reduce guide-hole wear over mating cycles.

Q: Can I field-clean MTP/MPO connectors if high insertion loss is detected during testing?

A: Yes, but field-cleaning requires specialized one-click cleaners designed specifically for multi-fiber MT ferrules (compatible with 8/12/16 fiber arrays). Standard single-fiber cleaners will damage guide pins or leave debris across parallel fiber cores. Inspect the end-face at 200x magnification post-cleaning.

Q: Are your MTP/MPO trunk cables compliant with CPR (Construction Products Regulation) for European data centers?

A: Yes. We supply cables meeting Euroclass ratings including Eca, Dca, Cca, and B2ca upon request, utilizing low-smoke zero-halogen (LSZH) compounds that comply with IEC 60332-3 and IEC 61034 standards.

Q: How are breakout legs protected during installation in high-density cable trays?

A: Breakout legs are anchored using a robust internal pulling stocking or an aluminum pulling eye attached directly to the main trunk body. This ensures pulling tension is absorbed by the aramid yarn strength members rather than the individual breakout tubing.

Q: What documentation is provided with bulk shipments?

A: Each shipment includes a serialized quality control certificate, individual insertion loss and return loss test sheets for every single assembly, and geometric compliance data confirming ferrule end-face parameters.

As one of the most experienced mtp mpo manufacturers and suppliers in China, we offer a wide range of products with superior quality. We warmly welcome you to buy high-grade mtp mpo in stock here and get quotation from our factory. For price consultation, contact us.

Send Inquiry